·Home ·Set Homepage ·Collects ·Webmap ·中文版 ·English  
 
   
海洋建材
   
    About us Equipment & Constructs Epoxy grounds Emery grounds Product Service Case Contact us  
Product
Construction craft
scene constructs
   
   
 
 
·You are now in:Home - Epoxy Grounds- Product  
 
 
Application
For floor where abrasion nd impact resistance as well as dust-proof are required such as for warehouse,pier,workshop,park,factory,garage,station,etc.

Performance characteristic
1, has the performance very high resistance to wear;
2, reduced dust;
3, the construction is convenient, is easy to maintain.

Application
For floor where adrasion and impact resistance as well as dust-proof are required such as for shed,Loading area at port,Machinery industry,Aircraft parking apron,Garage,Parking area,Oil storage plant,Pathway floor,Mine chute,Bridge surface,Reservoir overflow relief channel,Energy consumption,Loading slope,Military industry,Eeaving mils,Cold storage plant,Automobile industy,Electronic industry,Express highway,Etc.

Performance characteristic
After is completed the metal aggregate wear-resisting grounds around a house has below the characteristic:
1, extremely high resistance to wear;
2, permanent corrosion resistance;
3, reduced dust;
4, bears the impact;
5, guards against the static electricity, the misfiring;
6, the construction is convenient.

Construction craft
1, when not does in the even level leveling, aggregate evenly dusts in looks for on level;
2, the ground smooths by grinding;
3, saws the crack concrete in the suitable position, does the Expands and contracts Seam, and adds completely needs Fill crack material;
4, maintains the hardened ground.

 
Technical Index
ITEM
Index
Nonmetal aggregate
Metal aggregate
Wear resistant ≤650 ≤450
3Pressive strength,MPa 3d 49.2 49.2
7d 65.7 65.7
28d 77.0 77.0
Bnding strength,MPa > 9 > 11.5
Tensile strength,MPa 3.2 3.9
Hardness 7.0+0.5 8.0±0.5
Oil-proof   The strength will not be any lower after it is sonaked in oil for 3 years,Oil penetration is smaller than 0.3mm.(Including anti penetration)
Anti-corrosion   Standard salt corrosion test for aggregate:42d natural potential consistence is positive and stability value is +50mv(S.C.E.),Cement test body is soaked in 5% NaCl solution for two years and 3 months,There is no corrosion and no humid expansion crack.
  Same as ordinary cement floor Same as ordinary cement floor
Fire retard   No sparks and blasting (in accordance with the national stadare GB50209-95)
Anti-static electricity   The leakage resistance of test body is between 10 5 powers of exponent -10 6 powers Ω
 
Cross section chart for processing
 
     
 
TEL:0755-61101128  0755-27291710  FAX:0755-61101129  24 hours hot lines:Mr.Xu:(0)13302465988
 